Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. bras. ginecol. obstet ; 41(4): 236-241, Apr. 2019. tab
Article in English | LILACS | ID: biblio-1013605

ABSTRACT

Abstract Objective To compare sexual function and quality of life (QOL) among intrauterine contraceptive (copper-intrauterine device [Cu-IUD] or the 52-mg 20 μg/day levonorgestrel- releasing intrauterine system [LNG-IUS]) users. Methods This was part of a cross-sectional study. Women aged between 18 and 49 years old, in a heterosexual relationship, reporting sexual intercourse in the previous 4 weeks, using Cu-IUD (Group 1) or LNG-IUS (Group 2) responded to a questionnaire with sociodemographic information, to the Female Sexual Function Index (FSFI), to the World Health Organization QOL Questionnaire Abbreviated Version (WHOQOL-BREF), and to a questionnaire about the contraceptive method used. The Student t-test, the Pearson χ2 test or the Fisher exact test, and the Mann-Whitney test were used for the analysis. For the adjusted comparison, we have used the analysis of covariance (ANCOVA). A multiple regression analyzing factors related to FSFI 26.55 was done. Significance was established at p < 0.05. Results A total of 347 women in Group 1 (mean age of 32.3 ± 7.5 years old) and of 298 in Group 2 (mean age of 32.7 ± 6.4 years old) completed the questionnaires.Most women had ≥ 8 years of schooling, were in amonogamous relationship, and had had ≤ 2 pregnancies. A total of 122 Cu-IUD and of 87 LNG-IUS users scored ≤ 26.55 on the FSFI. Significant lower scores in physical, environmental, and overall QOL domains in the WHOQOL-BREF questionnaire were found in Group 1. More women using the Cu- IUD were not satisfied with the method. Conclusion We did not find significant differences in sexual function; there was a lower score in some domains of QOL among women who used the Cu-IUD. It was not possible to ensure that those differences were related to the contraceptive method.


Resumo Objetivo Comparar a função sexual e a qualidade de vida (QV) entre usuárias de contraceptivos intrauterinos (dispositivo intrauterino com cobre [DIU-cobre] ou sistema intrauterino liberador de levonorgestrel [SIU-LNG 52 mg 20 μg/dia]. Métodos O presente estudo foi parte de um estudo de corte transversal. Mulheres com idades entre 18 e 49 anos, em relacionamento heterossexual, relatando relação sexual nas 4 semanas anteriores, utilizando DIU-cobre (Grupo 1) ou SIU-LNG (Grupo 2) responderam ao questionário com informações sociodemográficas, ao Índice de Função Sexual Feminino (IFSF), ao Questionário de QV da Organização Mundial de Saúde, versão abreviada (WHOQOL-BREF, na sigla eminglês), e a umquestionário sobre ométodo contraceptivo utilizado criado para o presente estudo. Os testes t de Student, o teste χ2 de Pearson, o teste exato de Fisher e o teste de Mann-Whitney foram utilizados. A análise de covariância (ANCOVA) foi utilizada para a comparação ajustada. Foi realizada a análise de regressão logística multivariada analisando fatores associados ao IFSF ≤ 26.55. O nível de significância foi p < 0.05. Resultados Um total de 347 mulheres no Grupo 1 (idade média 32,3 ± 7,5 anos) e de 298 no Grupo 2 (idade média 32,7 ± 6,4 anos) completaram os questionários. A maioria das mulheres relatou ≥ 8 anos de escolaridade, estava emrelaçãomonogâmica e teve ≤ 2 gestações. Um total de 122 e de 87 usuárias do DIU-cobre e do SIU-LNG, respectivamente, pontuaram ≤ 26,55 no IFSF. Pontuações significativamente menores nos domínios físico, meio-ambiente e QV geral no WHOQOL-BREF foram encontrados no Grupo 1. Mais mulheres do Grupo 1 estavam insatisfeitas com o método. Conclusão Não encontramos diferenças na função sexual, entretanto havia menores pontuações em certos domínios da QV entre as usuárias do DIU-cobre. Não foi possível afirmar relação dessas diferenças com os métodos.


Subject(s)
Humans , Female , Adolescent , Adult , Young Adult , Quality of Life , Sexual Behavior , Intrauterine Devices/statistics & numerical data , Brazil , Cross-Sectional Studies , Surveys and Questionnaires , Cohort Studies , Levonorgestrel , Intrauterine Devices, Medicated/statistics & numerical data , Intrauterine Devices, Copper/statistics & numerical data , Middle Aged
2.
Evid. actual. práct. ambul ; 19(3): 97-98, 2016. ilus
Article in Spanish | LILACS | ID: biblio-1151451

ABSTRACT

La anticoncepción de emergencia se refiere al uso de medicación o a la inserción de un dispositivo intrauterino de cobre para prevenir el embarazo luego de una relación sexual no protegida o del fallo de un método anticonceptivo, en una mujer que no desea el embarazo. De entre las alternativas farmacológicas del método, se estima que el uso de levonorgestrel prevendría el 50% de los embarazos. A partir de una viñeta clínica, en la cual se describe el caso de una paciente obesa que resultó embarazada luego de utilizar anticoncepción hormonal de emergencia tras una relación sexual no protegida, se realizó una búsqueda bibliográfica para establecer la efectividad del método en pacientes con esta característica (obesidad). La búsqueda identificó un metaanálisis que relacionó al triple la probabilidad de embarazo en pacientes con índice de masa corporal superior a 30 kg/m2 que utilizaron anticoncepción de emergencia hormonal. (AU)


Emergency contraception refers to the use of medication or the insertion of a copper intrauterine device to prevent pregnancy after the occurance of unprotected sex intercourse or failure of a contraceptive method in a woman who does not desire pregnancy. Among the pharmacological alternatives of the method it is estimated that the use of levonorgestrel prevents 50% of pregnancies. From a clinical vignette, in which the case of an obese patient who became pregnant using hormonal emergency contraception after unprotected sex intercourse is described, a literature search was conducted to establish the effectiveness of the method in patients with this feature (obesity). The search identified a metaanalysis that shows an incresed probability (threetimes) of pregnancy in patients with body mass index greater than 30 kg/m2 that used hormonal emergency contraception. Emergency contraception is less effective in women with obesity. (AU)


Subject(s)
Humans , Female , Pregnancy , Adult , Contraceptives, Postcoital, Hormonal , Contraceptives, Postcoital, Synthetic , Obesity/complications , Pregnancy/statistics & numerical data , Body Mass Index , Meta-Analysis as Topic , Risk Factors , Levonorgestrel/administration & dosage , Contraceptives, Postcoital , Intrauterine Devices, Copper/statistics & numerical data , Norpregnadienes
3.
Indian J Med Sci ; 2010 Aug; 64(8) 349-355
Article in English | IMSEAR | ID: sea-145552

ABSTRACT

Context: Insertion pain or fear of it may make women hesitate to use the intrauterine device (IUD); a long-term, reversible, highly-effective contraception method. Further study has been recommended on the effects of lidocaine (xylocaine) gel on IUD insertion pain in the recent Cochran review. Aims: To determine the effect of lidocaine gel on pain from TCu-380AIUD insertion. Materials and Methods: At a health center in Tabriz, Iran, 96 women were allocated into 3 groups using block randomization with 6 and 9 block sizes considering allocation concealment. In 1 st group, lidocaine 2% gel and in the 2 nd , lubricant gel was placed in the cervical canal 1 minute before an IUD insertion, and the 3 rd group got no intervention. Immediately after IUD insertion, pain during the insertion was measured using 0-10 cm visual analogue scale. Statistical Analysis Used: Kruskal-Wallis and linear regression in SPSS-13 were used to identify effect of lidocaine gel on the pain. Results: Overall, the mean pain score was 3.5 ± 1.8. In univariate analysis, there was no significant difference in pain scores between the 3 groups. Also, results of linear regression model by controlling effect of the possible confounding showed no significant effect of lidocaine gel on the insertion pain. The mean pain score in the lidocaine group was 0.39 less than the no intervention group, but it was not significant (CI 95% of the difference: -1.3, 0.57). Conclusions: Use of 2% lidocaine gel into the cervical canal has no effect on reducing overall pain during IUD insertion.


Subject(s)
Adult , Female , Humans , Gels , Intrauterine Devices, Copper/adverse effects , Intrauterine Devices, Copper/statistics & numerical data , Iran , Lidocaine/administration & dosage , Lidocaine/therapeutic use , Pain/drug therapy
4.
Bol. Centro Biol. Reprod ; 17: 51-9, 1998. tab
Article in Portuguese | LILACS | ID: lil-247713

ABSTRACT

Atualizaçäo dos dados da pesquisa sobre o dispositivo intrauterino (DIU) liberador de 20 mcg/dia de levonorgestrel (DIU-LNG) comparado com o DIU de cobre, TCu 380A, em estudo multicêntrico da Organizaçäo undial da Saúde (OMS), desenvolvida na Maternidade Therezinha de Jesús e no CEPECS, para o Centro de Biologia da Reproduçäo da UFJF. Em 200 mulheres, foram avaliados os índices de continuaçäo, os abandonos, os efeitos colaterais e outros eventos ao longo de 4 anos com 3972 meses/mulher para o TCu 380A e com 3544 meses/mulher de observaçäo com o DIU-LNG. Neste período houve 21 descontinuaçöes com o TCu 380A e 35 com o DIU-LNG. Considerando-se que 19 usuárias pediram para retirar o DIU porque queriam nova gestaçäo o índice de continuaçäo com os dois DIUs é bastante aceitável (79 por cento com o DIU de cobre e 65 por cento com o DIU-LNG). Os efeitos colaterais mais frequentes com o uso do DIU-LNG foram o sangramento irregular e a amenorréia, mas apenas 6 tiveram seu DIU removido por esta causa, as demais aceitaram continuar. Näo houve neste período nenhuma gravidez, e apenas 4 pacientes foram perdidas no seguimento. O DIU-LNG por sua alta eficácia e poucos efeitos colaterais é uma promessa de um novo e excepcional método contraceptivo.


Subject(s)
Humans , Intrauterine Devices, Medicated/statistics & numerical data , Dimethylpolysiloxanes/therapeutic use , Intrauterine Devices, Copper/statistics & numerical data
5.
Caracas; s.n; sept. 1997. 19 p. ilus, tab.
Thesis in Spanish | LILACS | ID: lil-225724

ABSTRACT

Se realizó un estudio clínico, prospectivo y comparativo en 140 pacientes sometidas a operación cesárea. A 70 se les aplicó el dispositivo intrauterino (DIU) T Cu 380 A y a las 70 restantes sólo se les realizó la operación sin aplicar el DIU. Los parámetros evaluados durante el puerperio mediato fueron el dolor, el sangrado y la infección de ambos grupos, y a los 40 días de visualización de los hilos o expulsión de DIU, en el grupo en estudio, no se encontraron diferencias significativas en los resultados, lo cual sugiere que en una adecuación selección de las pacientes, la inserción del DIU transcesárea es un método seguro para el control de la fertilidad


Subject(s)
Humans , Female , Pregnancy , Cesarean Section/methods , Gynecology , Intrauterine Devices, Copper/statistics & numerical data , Obstetrics
6.
Bol. Centro Biol. Reprod ; 16: 41-6, 1997. tab
Article in Portuguese | LILACS | ID: lil-221151

ABSTRACT

Experiência de 6 anos, com 178 usuárias do novo dispositivo intrauterino GyneFix é relatada, com o objetivo de verificar se este dispositivo apresenta alguma melhora em relaçäo aos novos DIUs existentes no mercado. Com mais de 6100 meses - mulher de observaçäo, pode-se sugerir que as expectativas do inventor do GyneFix foram em parte concretizadas: näo houve descontinuaçäo por dor ou processo inflamatório pélvico e ocorreu uma queda nas expulsöes (0,7 por cem mulheres/ano), sendo mantida a eficácia contraceptiva (0,8 por 100 mulheres/ano); no entanto näo melhora significativamente o volume de perda sanguínea menstrual em relaçäo ao DIU TCu 380A, e näo houve alteraçäo nos estoques de ferro do organismo (medidos pela ferritina sérica) pelo menos nos dois primeiros anos de uso. Deve-se chamar a atençäo que a aplicaçäo do GyneFix requer treinamento especial para evitar as falhas nas inserçöes e resta a preocupaçäo de uma expulsäo näo percebida pela usuária, com a possibilidade de gravidez subsequente.


Subject(s)
Humans , Female , Adolescent , Adult , Middle Aged , Intrauterine Devices, Copper/statistics & numerical data , Contraception/instrumentation
7.
Quito; FCM; 1995. 25 p. ilus, tab.
Monography in Spanish | LILACS | ID: lil-188644

ABSTRACT

El método anticonceptivo más utilizado en nuestra población es el DIU. Por tal motivo nuestro trabajo se basa en los embarazos que ocurrieron en mujeres con implante del DIU. Tomando en cuenta las tasas internacionales, los embarazos con la TCu 380 son menores al 1 por cada 100 mujeres en el 1er año llegando al 1.4 después de 6 años de uso. En nuestro medio la incidencia llegó al 0.8 por ciento en el 2do año y sube al 1.9 por ciento al 3er y 4to año de uso, por esta razón la afectividad de este dispositivo es alta en relación al TCu 200 y ASA Lippes. La TCu 200 tiene una incidencia de embarazos de 1.7 por ciento en el 1 año, de 2 a 4 por ciento entre el 2do y 3er año y en el cuarto año se piensa que el dispositivo ha perdido su efectividad, teniendo una tasa de 2.2 por ciento. El ASA Lippes al tener una taza de embarazos del 6 al 8 por ciento, ha perdido interés entre las usuarias.


Subject(s)
Humans , Female , Pregnancy , Contraceptive Devices , Contraceptive Devices, Female , Intrauterine Devices, Copper/statistics & numerical data , Pregnancy , Pregnancy Complications
8.
Ginecol. obstet. Méx ; 55: 107-10, oct. 1987. tab
Article in Spanish | LILACS | ID: lil-104087

ABSTRACT

Se revisaron los eventos presentados por 600 mujeres adolescentes de 14 a 19 años de edad que voluntariamente aceptaron la inserción de un dispositivo intrauterino (DIU) como método de control de la fertilidad. Los datos de 1831 mujeres adultas (20 o más años) con el mismo método sirvieron de comparación. Los DIUs aplicados fueron "T" liberadoras de cobre en 58% de los casos. "T" liberadoras de progesterona en 37.8% y asa de Lippers en el 1.9%. Las tasas netas de eventos acumulados a un año por cien aceptantes por tipo de terminación y continuación para las adolescentes y adultas resultaron de: Embarazo 1.4, expulsión 2.0 y2.0 de retiros por causas médicas 3.2 y 3.1 respectivamente. Diferencias sin significancia estadística. En esta muestra de mujeres adolescentes, el uso del DIU mostró bajas tasas de abandono, similares a las presentadas por la muestra de mujeres adultas. No se encontraron casos de enfermedad inflamatoria pélvica, ni se presentaron perforaciónes uterinas. Su uso puede recomendarse porque la baja tasa de embarazos accidentales y la elevada tasa de continuidad garantizan una protección anticonceptiva eficaz


Subject(s)
Adolescent , Adult , Humans , Female , Intrauterine Devices, Copper/statistics & numerical data , Intrauterine Devices, Copper/statistics & numerical data , Intrauterine Devices/etiology , Intrauterine Devices/statistics & numerical data , Mexico , Parity , Urban Population/statistics & numerical data
SELECTION OF CITATIONS